Magnum MS4448PAE 4400 Watt 48V- Parallel Inverter 60 A PFC Charger
Inverter Specifications.
- Input battery voltage range 36.0 - 67.6 VDC.
- Nominal AC output voltage 120/240 VAC split phase.
- Output frequency and accuracy 60 Hz 0.04%.
- Total Harmonic Distortion (THD) < 5% <.
- 1 msec surge current (amps AC) Line-Neutral: 120, Line-Line: 160.
- 100 msec surge current (amps AC) 92 Line-Neutral: 75, Line-Line: 90.
- 5 sec surge power (real watts) 8500.
- 30 sec surge power (real watts) 6000.
- 5 min surge power (real watts) 5400.
- 30 min surge power (real watts) 4800.
- Continuous power output at 25° C 4400 VA.
- Maximum continuous input current 122 A.
- Inverter efficiency (peak) 94%.
- Transfer time 16 msecs 1.
- Search Mode < 6 watts.
- No Load (120 VAC output) 25 watts.
- Waveform Pure Sine Wave.
Charger Specifications.
- Continuous output at 25° C 60 ADC.
- Charger efficiency 85%.
- Power factor > 0.95.
- Input current at rated output (AC amps) 17.5 AAC per leg at 120/240 VAC split phase.
General Features and Capabilities.
- Transfer relay capability 2 legs at 30A per leg transfer standard on all models.
- Five stage charging capability Bulk, Absorb, Float, Equalize (requires remote), and Battery Saver.
- Battery temperature compensation With available temp sensor (battery temp 0 50° C).
- Internal cooling 0 to 120 cfm variable speed drive using dual 92mm brushless DC fans.
- Overcurrent protection Yes, with two overlapping circuits.
- Overtemperature protection Yes on transformer, MOSFETS, and battery.
- Conformal coating on PCB's for corrosion protection Yes.
- Powder coated chassis and top for corrosion protection Yes.
- Stainless steel fasteners for corrosion protection Yes.
Physical Specifications.
- Dimensions (l x w x h) 13.75 x 12.65 x 8.0 (34.9 cm x 32.1 cm x 20.3 cm).
- Mounting Shelf or wall (no vents on bottom).
- Max operating altitude 15,000' (4570 m).
Model: MS4448PAE
|
|